Transcript of Whirlpool WGPH45 AM Installation manual

INSTALLATION INSTRUCTIONS FOR PACKAGE HEAT PUMP OR PACKAGE COOLING UNIT Table of Contents HEAT PUMP/ELECTRIC COOLING SAFETY...............................1 SEQUENCE OF OPERATION ........................................................7 Start-up Procedure--Cooling Cycle ............................................7 INSTALLATION REQUIREMENTS ................................................2 Start-up Procedure--Heat Pump ................................................8 Tools and Parts ............................................................................2 Final System Checks....................................................................8 Location Requirements ................................................................2 Explanation and Guidance--Heat Pump.....................................8 Ductwork Requirements ..............................................................4 Defrost Cycle................................................................................9 Electrical Requirements ...............................................................4 System Troubleshooting ............................................................10 Circulating Air Blower.................................................................11 INSTALLATION INSTRUCTIONS ..................................................4 Blower Performance Data ..........................................................12 Inspect Shipment .........................................................................4 Place Heat Pump or Air Conditioning Unit in Final Location.......5 CHARGE VERIFICATION .............................................................14 Connect Condensate Drain .........................................................5 Install Ductwork............................................................................5 SYSTEM MAINTENANCE ............................................................16 Filters ............................................................................................5 Electric Heat Installation and Adjustment....................................6 TROUBLESHOOTING ..................................................................17 Make Electrical Connections .......................................................6 Complete Installation ...................................................................7 ASSISTANCE OR SERVICE .........................................................20 Accessories ................................................................................20 HEAT PUMP/ELECTRIC COOLING SAFETY Recognize this symbol as a safety precaution. Please adhere to the following warnings and cautions when installing, adjusting, altering, servicing or operating this unit. ATTENTION INSTALLATION PERSONNEL Prior to installation, thoroughly familiarize yourself with this installation manual. Observe all safety warnings. During installation or repair, caution is to be observed. It is your responsibility to install the product safely and to educate the customer on its safe use. Recognize Safety Symbols, Words and Labels WARNING The following symbols and labels are used throughout this manual to Hazards or unsafe practices could result in property indicate immediate or potential hazards.It is the owner's responsibility to read and comply with all safety information and Goodman 1 damage, product damage, severe personal injury or death. instructions accompanying these symbols. Failure to heed safety CAUTION information increases the risk of serious personal injury or death, property damage and/or product damage. Hazards or unsafe practices may result in property damage, product damage, personal injury or death. Placeho CAUTION for Ba Goodman 9 Code Hazards or unsafe practices may result in property Whirlpool Gold(R) Models or product damage. WGPH45**AM, WPC45**AM Tradewinds Distributing Company, LLC WPIO-362 14610 Breakers Drive Jacksonville, FL 32258

Ground Level Preinstallation Details The ductwork must be placed into the roof curb before mounting the package unit. The unit should be set on a solid, level foundation, preferably a concrete slab at least 4" (10.2 cm) thick. The slab should be Roof Curb G 2009 ENV3 above ground level and surrounded by a graveled area for good drainage. Any slab used as a unit's foundation should not adjoin the building, since it is possible that sound and vibration may be transmitted to the structure. Rooftop Preinstallation Details Check that the roof is weathertight and allows proper drainage of condensation. Use steel or treated wood beams as unit support for load distribution. NOTE: To ensure proper condensate drainage, the unit must be installed in a level position. To avoid possible property damage or personal injury, the roof must have sufficient structural strength to carry the weight of the unit(s) and snow or water loads as required by local codes. Consult a structural engineer to determine the weight capabilities of the roof. The unit may be installed directly on wood floors or on Class A, Class B, or Class C roof covering material. To avoid possible personal injury, a safe, flat surface for service personnel should be provided. Rooftop Installation Roof Curb Installations Only Minimum Clearances NOTES: The unit is designed to be located outside the building with an Sufficient structural support must be determined prior to unobstructed condenser air inlet and discharge. Additionally, the locating and mounting the curb and package unit. unit must be situated to permit access for service and installation. Curb insulation, cant strips, flashing and general roofing material are furnished by the contractor. Condenser air enters from 3 sides. Air discharges upward from the top of the unit. Refrigerant gauge connections are made on Curbing must be installed in compliance with the National the right-hand side of the unit as you face the compressor Roofing Contractors Association Manual. compartment. Construct ductwork using current industry guidelines. Electrical connections can be made on the right-hand side of the unit. The best and most common application is for the unit to be located 10" (25.4 cm) from the wall (4" [10.2 cm] minimum) with the connection side facing the wall. This close-to-the-wall application minimizes exposed wiring. Close-to-the-wall application assures free, unobstructed air to the other 2 sides. In more confined application spaces, such as corners, provide a minimum 10" (25.4 cm) clearance on all air inlet sides. Allow 18" (45.7 cm) minimum for service access to the compressor compartment and controls. The top of the unit should be completely unobstructed. If the unit is to be located under an overhang, there should be a minimum of 36" (91.4 cm) clearance and provisions made to deflect the warm discharge air out from under the overhang. 3

Minimum Clearances Down Discharge Applications 10" Cut insulation around bottom openings and remove panels from (25.4 cm) the bottom of the unit, saving the screws holding the panels in place. A NOTE: Single phase models require installation of horizontal duct B kit #20464501PDGK (medium chassis) and #20464502PDGK (large chassis). Panel Removal 36" (91.4 cm) 36" C 36" (91.4 cm) (91.4 cm) B A. Wall A B. Unit C. Curb A. Supply air panel B. Return air panel Ductwork Requirements Electrical Requirements Install all conditioned air plenums, ducts and air filters in accordance with NFPA 90B Standard for the Installation of WARNING Warm Air Heating and Air-Conditioning Systems (latest edition). HIGH VOLTAGE! The heat pump or air conditioning unit is provided with Disconnect ALL power before servicing. flanges for the connection of the plenum and ducts. Multiple poweGr soooudrcmesamna6y be present. All air filters must be listed as Class 2 air filters. Failure to do so may cause property damage, All ductwork must be made of materials and insulated to personal injury or death. meet local, state and national codes. Ductwork installed outdoors must be sealed, weatherproof and sheltered against NOTE: All outdoor wiring must be suitable for outdoor use. Use physical damage. Caulking, flashing or other means of copper conductors only. adequately providing a permanent weather seal should be All field wiring must be done in accordance with National used where duct penetrates a building or structure opening. Electrical Code requirements, applicable requirements of UL, Airflow Conversion or local codes, where applicable. Electrical wiring, disconnect means and over-current Units can easily be converted from horizontal to downflow airflow protection are to be supplied by the installer. Refer to the delivery. In downflow or high static installations, the installer rating plate for the maximum over-current protection, should measure the total external static and review the blower minimum service ampacity, and operating voltage. See the performance charts before performing the installation. In some wiring connection diagrams in "Troubleshooting." installations it will be necessary to change the blower speed to This heat pump or air conditioning unit must be electrically provide proper airflow. grounded in accordance with National Electric Code (ANSI/ NFPA 70) requirements, applicable requirements of UL, or local Horizontal Airflow codes, where applicable. Single phase models are shipped without horizontal duct covers. If needed, these kits may be ordered through your local supplier. INSTALLATION INSTRUCTIONS Inspect Shipment Be sure to examine the heat pump or air conditioning unit inside the carton if the carton is damaged. This heat pump or air conditioning unit is shipped in one package, completely assembled and wired. The indoor If damage is found, it should be noted on the carrier's freight thermostat and accessories are shipped in a separate carton bill. Damage claims should be filed with the carrier when ordered. immediately. Claims of shortages should be filed with the seller within 5 days. Check the heat pump or air conditioning unit rating plate to confirm specifications are as ordered. NOTE: If any damages are discovered and reported to the carrier, do not install the heat pump or air conditioning unit, since your Upon receipt of heat pump or air conditioning unit, inspect it claim may be denied. for possible shipping damage. 4