Size :367.93 KB
Page{s) : 1
Create Date : February 24, 2011

Transcript of Whirlpool Wgd7600xw Quick Specs

Gas Dryer PRODUCT MODEL NUMBERS OVERALL DIMENSIONS WGD7300X, WGD7400X, WGD7600X, WGD7800X Dryer dimensions Dryer with extended back: Dryer with flat back: 30" 221/4" 28" (762 mm) (565 mm) (711 mm) Gas supply: This dryer is equipped for use with Natural gas. 431/2" Dryer can be converted to L.P. gas. When rigid pipe is used (783 mm) it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for NOTE: Most installations require a minimum of 5" (127 mm) clearance lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 behind dryer for exhaust vent with elbow. See "Venting Requirements." m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An Spacing for recessed area or closet installation individual manual shutoff valve must be installed within 6 All dimensions show recommended spacing allowed, with ft (1.8 m) of the dryer in accordance with the National Fuel tested spacing of 0" (0 mm) clearance on sides and rear. Gas Code ANSI Z223.1. Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result. Exhaust venting: Exhaust your dryer to the outside. 4" 14" max.* (102 mm) diameter vent is required. Rigid or flexible metal (356 mm) exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Recommended Styles: Acceptable Style: 18"* (457 mm) Louvered Hood Box Hood Angled Hood The Vent system chart provides venting requirements 1" 29" 1" 1" 30" 5" that will help achieve best drying performance. (25 mm) (737 mm) (25 mm) (25 mm) (762 mm) (127 mm) NOTE: Bottom exhaust installations have a 90 turn Recessed area Side view - closet or confined area inside the dryer. To determine maximum exhaust length, (Dryer with extended back) add one 90 turn to the chart. Vent system chart 14" max.* 48" 2* (356 mm) (310 cm2) Number of Type Box/louvered Angled 3"* 90 elbows of vent hoods hoods (76 mm) 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 3"* (76 mm) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 24" 2* (155 cm2) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 1" 5" (25 mm) (127 mm) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 28" (711 mm) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) Side view - closet or confined area Closet door with vents (Dryer with flat back) Do not use vent runs longer than specified in vent * Required spacing length chart. For closet installation, with a door, the minimum ventilation openings in the top Select the route that will provide the straightest and and bottom of the door are required. Louvered doors with equivalent air ventilation most direct path outdoors. openings are acceptable. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90 turns possible. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation Ref. W10347751B our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. 02/2011