MULTIPOSITIONAL CASED EVAPORATOR COIL INSTALLATION INSTRUCTIONS Table of Contents EVAPORATOR COIL SAFETY .......................................................1 Verify Orifice Size .........................................................................3 Assemble Distributor/Orifice ........................................................3 INSTALLATION REQUIREMENTS ................................................2 Install Evaporator Coil ..................................................................3 Tools and Parts ............................................................................2 Field Conversion for Horizontal Airflow........................................5 System Requirements..................................................................2 Install Auxiliary Drain Pan (If required) .........................................5 Location Requirements ................................................................2 Install Condensate Drains ............................................................6 Drain Requirements .....................................................................2 Connect Refrigerant Lines ...........................................................6 INSTALLATION INSTRUCTIONS ..................................................2 ASSISTANCE OR SERVICE ...........................................................6 Inspect Shipment .........................................................................2 Prepare Evaporator Coils.............................................................3 WARRANTY ....................................................................................7 EVAPORATOR COIL SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." These words mean: You can be killed or seriously injured if you don't immediately follow instructions. You can be killed or seriously injured if you don't follow instructions. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low-level exposure to one of the substances listed: formaldehyde. 065715702

Prepare Evaporator Coils Orifice Extension Stub--After Removal of Shipping Strap A IMPORTANT: B This evaporator coil was manufactured containing a dry air precharge of 10 psi. Slowly remove the rubber line seal plugs A. Orifice extension stub to relieve the dry air precharge pressure. B. Ring seal Before installation, wash the coil finned areas with a mild soap solution to remove shipping and handling contamination. 5. Slide the brass hex nut over the orifice extension stub. A B C A D G F E A. Distributor fitting D. Orifice extension stub F. Brass hex fitting B. Piston orifice E. 0.812" Brass hex nut G. Mounting flange B C C. Ring seal (supplied) A. Evaporator coil inside housing 6. If a change in orifice is required, remove the factory-installed B. Left horizontal drain connections orifice with an orifice extractor tool. C. Right horizontal drain connections 7. Insert the proper orifice into the fitting, seal end first. Make Verify Orifice Size sure the orifice is free to move in the fitting. IMPORTANT: The proper orifice size is dependent on indoor coil/ 8. Assemble the brass hex nut and orifice extension stub onto outdoor unit combination and application. Consult the outdoor the distributor/orifice assembly as shown. unit information to determine if the indoor unit has the correct orifice installed. NOTE: Overtightening the brass hex nut will crush the gasket and might result in a system leak or stuck piston. Assemble Distributor/Orifice 9. Dispose of/recycle all packaging and unused parts. 1. Remove the brass hex nut from distributor/orifice assembly. 2. Remove the line seal plug from the orrifice assembly. Install Evaporator Coil 3. Unscrew and remove the shipping strap from the orifice IMPORTANT: extension stub. Remove the orifice extension stub from the panel. The evaporator coil must be installed in the discharge 4. Relocate the ring seal to the stub end of the orifice extension (supply) air of a gas or oil furnace. Do not install an stub as shown. evaporator coil in the return air, or excessive condensation will occur within the furnace. Orifice Extension Stub--Before Removal of Shipping Strap Install the evaporator coil level with the drain connection to A ensure proper drainage. B To avoid damage to the plastic drain pan, minimum spacing is required between the drain pan and a furnace heat exchanger. A minimum spacing of 2" (5.1 cm) is required for a gas furnace. A minimum spacing of 4" (10.2 cm) is required for an oil-fired furnace. See "Evaporator Coil Drain Pan Clearances." Evaporator Coil Drain Pan Clearances C C. Ring seal A B A. Orifice extension stub B. Shipping strap C A. Furnace heat exchanger B. Gas--2" (5.1 cm) minimum; Oil-fired--4" (10.2 cm) minimum C. Plastic drain pan 3

Vertical Installations Install Splash Shield--Horizontal Installation 1. Insert lip of splash shield behind drain pan edge. 2. Align splash shield so that it slopes toward the horizontal drain pan. A A B B C C A. Evaporator coil--inside housing D B. Left horizontal drain connections C. Right horizontal drain connections A. Splash shield C. Water trough B. Slope of splash shield D. Horizontal drain pan Horizontal Installations 3. Using holes in splash shield as a guide, drill four " (3.2 mm) holes into coil duct mounting flange. Position the evaporator coil on the outlet of the furnace using sheet metal screws. B A The evaporator coil should be level, or pitched slightly toward the drain connection. C Airflow should be set to 350 CFM per ton. A. Holes for mounting splash shield to duct flanges when horizontal drain pain is flush with top of housing Install splash shield (provided) on the evaporator coil outlet. The bottom flange of the splash shield should rest on the B. Holes for mounting splash shield to duct flanges when horizontal horizontal drain pan. The sides of the splash shield should be drain pan is 2" (5.1 cm) shorter than top of housing. attached to the duct flanges with sheet metal screws (not provided). See "Install Splash Shield--Horizontal C. Do not use these holes. Installation." 4. Fasten the splash shield to the duct mounting flange with A B C 4 sheet metal screws (field supplied). C E D A B F A. Splash shield D. Evaporator coil--counterflow horizontal application-- B. Evaporator coil--standard right-hand installation shown, horizontal application-- left-hand installation typical left-hand installation shown, right-hand installation typical E. Transition C. Furnace F. 12" (30.5 cm) minimum NOTE: All horizontal applications must have splash shield attached to coil case. A C A. Duct flange C. Splash shield B. Sheet metal screws 4