Transcript of Whirlpool 819041994 Use & care guide

(R) THROUGH-THE-WALL AIR CONDITIONER Use & Care Guide For questions about features, operation/performance, parts, accessories or service call: 1-800-253-1301. In Canada, call for assistance 1-800-461-5681, for installation and service, call: 1-800-807-6777 or visit our website at... www.whirlpool.com or...www.whirlpoolappliances.ca CLIMATISEUR ENCASTRE DANS LE MUR Guide d'utilisation et d'entretien Au Canada, pour assistance composez le : 1-800-461-5681, pour installation ou service, le : 1-800-807-6777 ou visitez notre site web a... www.whirlpoolappliances.ca Table of Contents/Table des matieres ................ 2 819041994 / 1188177

IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions: Plug into a grounded 3 prong outlet. Do not use an extension cord. Do not remove ground prong. Unplug air conditioner before servicing. Do not use an adapter. Use two or more people to move and install air conditioner. SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Parts supplied Read and follow the instructions provided with any tools listed Check that all parts are included in parts package. here. Tools needed s Tape measure A AC Parts Supplied 5A.eps s Flat-blade and Phillips s Drill and " or smaller bit screwdrivers s Utility knife B s Scissors s Pliers s Level D C E F G H I J K L A. Narrow trim frames (4) G. Universal top/bottom trim B. Insulating foam seals (4) frames (2.7" wide) (2) C. New grille D. #8 - 32 self-tapping screws (6) H. Screws with washers (4) E. Plastic grille I. Horizontal insulation strips (2) F. Universal side trim frames J. Vertical insulation strips (2) K. Baffle (3.1" wide) (2) L. Support blocks (2) 3

Location Requirements Power supply cord Wiring requirements IMPORTANT: Observe all governing codes and ordinances. " s 115-volt (103.5 min. - Check the location where the air conditioner will be installed. (0.6 cm) 126.5 max.) Proper installation is your responsibility. Make sure you have everything necessary for correct installation. s 7.6-12 amps The location should provide: s 15-amp time-delay fuse or s Grounded electrical outlet within 4 ft (122 cm) of where the circuit breaker power cord exits the air conditioner. s Use on single outlet circuit only. NOTE: Do not use an extension cord. s Free movement of air in room to be cooled. s 230/208 volt (197.6 min. - s A large enough opening for the air conditioner and sleeve 253 max.) (sold separately). s Adequate wall support for weight of air conditioner. s 0-12 amps s 15-amp time-delay fuse or Electrical Requirements circuit breaker WARNING s Use on single outlet circuit only. Electrical Shock Hazard Recommended ground method Plug into a grounded 3 prong outlet. Do not remove ground prong. This air conditioner must be grounded. This air conditioner is Do not use an adapter. equipped with a power supply cord having a grounded 3 prong Do not use an extension cord. plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in Failure to follow these instructions can result in accordance with all local codes and ordinances. If a mating outlet death, fire, or electrical shock. is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical The electrical ratings for your air conditioner are listed on the installer. model and serial number label. The model and serial number It is the customer's responsibility: label is located behind the front panel on the front flange above s To contact a qualified electrical installer. the coil area. s To assure that the electrical installation is adequate and in Specific electrical requirements are listed in the chart below. conformance with National Electrical Code, ANSI/NFPA 70 - Follow the requirements for the type of plug on the power supply latest edition, and all local codes and ordinances. cord. Copies of the standards listed may be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 Power Supply Cord NOTE: Your unit's device may differ from the one shown. B A Power supply cord Wiring requirements RESET TEST s 115-volt (103.5 min. - A. Reset button 126.5 max.) B. Test button s 0-7.5 amps This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art s 15-amp time-delay fuse or electronics that sense leakage current. If the cord is crushed, the circuit breaker electronics detect leakage current and power will be disconnected in a fraction of a second. s Use on single outlet circuit only. 4